205 - 16761 91 Street NW · KLARVATTEN
19 mars 2026
Pass1. Observed a wet, used cleaning cloth mounted on a countertop. Corrected during inspection. PHI directed staff onsite to remove wet cloth, clean and sanitize the affected area., , Action Required:, Please store wet, used cleaning cloths in approved sanitizer solutions when not in use, to prevent cross contamination of food contact surfaces., , Resource:, AHS guidelines on using wiping cloths, -https://www.albertahealthservices.ca/assets/wf/eph/wf-eh-guidelines-wiping-cloths.pdf, , 2. QUATs sanitizer was 400ppm and higher than the approved concentration of 200ppm. PHI coached staff onsite on mixing 200 ppm QUAT sanitizer., , Action Required:, Please ensure approved food contact surface sanitizers (100ppm Bleach, 200ppm QUATs, 12.5-25ppm Iodine) are readily available when in operation, to facilitate effective cleaning and sanitizing procedures., , Resource:, How to mix an approved sanitizing solution, -https://www.albertahealthservices.ca/assets/wf/eph/wf-eh-how-mix-an-approved-sanitizing-solution.pdf
Hand sink basin was obstructed by multiple items (rubber gloves, test strips' container and sanitizer dispenser hoses). Corrected during inspection. PHI directed staff onsite to remove all items that were blocking the hand sink basin at the time of inspection., , Action Required:, Do not store any items in hand sink basins or around the hand sink, to ensure easy accessibility of the hand sink at all times, to promote handwashing.
Ceiling surfaces throughout the kitchen had accumulated fuzz and dirt. , , Action Required: , Thoroughly clean affected area by April 2, 2026.
1. Pest control reports or program not available onsite at the time of inspection. , , Action Required:, Please implement an effective integrated pest control program. Conduct routine pest control monitoring activities and complete related reports when in operation. , , Email PHI a copy of your most recent pest control report by April 2, 2026., , , 2. No evidence of pest activity noted at time of inspection.
A ceiling panel was missing by the emergency light close to the kitchen entrance., , Action Required:, Repair or replace missing tile by April 16, 2026. Email PHI when corrective actions are complete, to prompt an onsite inspection.
Overdue Since Feb 19, 2024. Please correct immediately!, 1. A large hole in the wall was still present near the back handwashing sink. , , Action Required: , Ensure that the hole is sealed to keep the surface smooth, moisture resistant and easy to clean. Please notify PHI when the sealed to prompt an onsite inspection., , , 2. Shatter-proof bulbs had been installed where the ceiling light cover was missing.
Observed a single-use, disposable plastic tumbler and a scoop stored in direct contact with bulk flour. Corrected during inspection. No visible contamination noted. Flour allowed to be out back into service. PHI directed staff to discard the single-use disposable tumbler and stop re-using disposable utensils., , Action Required:, Do not reuse empty food containers as scoops. Do not use bowls as scoops. Do not reuse, single-use disposable utensils and do not store utensils in food containers to reduce the risk of cross contamination of food.